{"title":"SUBSTATION CONTROL CABLE","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eSubstation Control Cables\u003c\/strong\u003e are heavy-duty, multi-conductor signaling cables engineered specifically for the harsh electrical environments of utility substations and generation facilities. Operating at 600V, these cables connect critical control circuits, protective relays, automated switchgear, and monitoring instruments. Because they run parallel to high-voltage transmission lines, they are manufactured with robust shielding systems—typically heavy copper tape or aluminum foil with a tinned copper braid—to mitigate the severe effects of electromagnetic interference (EMI) and radio frequency interference (RFI). Encased in rugged, flame-retardant, and sunlight-resistant jackets like PVC or CPE, these cables are fully rated for installation in cable trays, direct burial, or underground ducts.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eNeed a quote? \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eCall us at:\u003c\/span\u003e 833-268-8644 \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(64, 64, 64);\"\u003eor e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003email: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003esales@wireamerica.com\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"18-12-shielded-substation-control-cable-15-10-pe-pvc","title":"18\/12 Shielded Substation Control Cable - 15\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 18 AWG, 12-conductor shielded substation control cable is a high-performance utility cable engineered for multi-circuit supervisory control, secondary metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a specialized 15\/10 PE\/PVC insulation system and a heavy-duty copper tape shield. This construction provides exceptional dielectric strength, a compact profile, and critical protection against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18\/12 Shielded 15\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eCompact 15\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 15 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection. This thinner insulation profile allows for reduced overall cable diameter and easier routing in high-density terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a continuous, low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Consolidating multiple digital or analog low-current signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting secondary arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects, SCADA RTU loops, and power monitoring circuits operating near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\" id=\"p-rc_7e2f41d6dad92cd1-164\"\u003e\u003cspan class=\"citation-425\"\u003e\u003c\/span\u003e\u003cspan class=\"citation-425 citation-end-425\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003csup class=\"superscript\" data-turn-source-index=\"1\"\u003e\u003c!----\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003cspan class=\"citation-423\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 15 mils PE \/ 10 mils PVC (Total 25 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 12-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470063427898,"sku":"SUB18-12SH-15\/10-250","price":582.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470063460666,"sku":"SUB18-12SH-15\/10-500","price":1157.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470063493434,"sku":"SUB18-12SH-15\/10-1K","price":2301.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470063526202,"sku":"SUB18-12SH-15\/10-FT","price":2.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-12-shielded-substation-control-cable-15-10-pe-pvc.jpg?v=1779141465"},{"product_id":"18-7-shielded-substation-control-cable-15-10-pe-pvc","title":"18\/7 Shielded Substation Control Cable - 15\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 18 AWG, 7-conductor shielded substation control cable is a high-performance utility cable engineered for multi-circuit supervisory control, secondary metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a specialized 15\/10 PE\/PVC insulation system and a heavy-duty copper tape shield. This construction provides exceptional dielectric strength, a compact profile, and critical protection against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18\/7 Shielded 15\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eCompact 15\/10 Composite Insulation:\u003c\/b\u003e Each of the 7 conductors is insulated with 15 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection. This thinner insulation profile allows for reduced overall cable diameter and easier routing in dense terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a continuous, low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Consolidating multiple digital or analog low-current signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting secondary arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects, SCADA RTU loops, and power monitoring circuits operating near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e White with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 15 mils PE \/ 10 mils PVC (Total 25 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 7-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470063264058,"sku":"SUB18-7SH-15\/10-250","price":508.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470063296826,"sku":"SUB18-7SH-15\/10-500","price":1010.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470063329594,"sku":"SUB18-7SH-15\/10-1K","price":2009.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470063362362,"sku":"SUB18-7SH-15\/10-FT","price":2.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-7-shielded-substation-control-cable-15-10-pe-pvc.jpg?v=1779141341"},{"product_id":"18-3-shielded-substation-control-cable-15-10-pe-pvc","title":"18\/3 Shielded Substation Control Cable - 15\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 18 AWG, 3-conductor shielded substation control cable is a high-performance utility cable engineered for multi-circuit supervisory control, secondary metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a specialized 15\/10 PE\/PVC insulation system and a heavy-duty copper tape shield. This construction provides exceptional dielectric strength, a compact profile, and critical protection against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18\/3 Shielded 15\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eCompact 15\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 15 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection. This thinner insulation profile allows for reduced overall cable diameter and easier routing in dense terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a continuous, low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Transmitting digital or analog low-current signals between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting secondary arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects, SCADA RTU loops, and power monitoring circuits operating near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 15 mils PE \/ 10 mils PVC (Total 25 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 3-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470063001914,"sku":"SUB18-3SH-15\/10-250","price":308.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470063034682,"sku":"SUB18-3SH-15\/10-500","price":613.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470063067450,"sku":"SUB18-3SH-15\/10-1K","price":1219.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470063100218,"sku":"SUB18-3SH-15\/10-FT","price":1.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-3-shielded-substation-control-cable-15-10-pe-pvc.jpg?v=1779141522"},{"product_id":"18-4-shielded-substation-control-cable-15-10-pe-pvc","title":"18\/4 Shielded Substation Control Cable - 15\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"1\"\u003eThis 18 AWG, 4-conductor shielded substation control cable is a high-performance utility cable engineered for multi-circuit supervisory control, secondary metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a specialized 15\/10 PE\/PVC insulation system and a heavy-duty copper tape shield. This construction provides exceptional dielectric strength, a compact profile, and critical protection against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18\/4 Shielded 15\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eCompact 15\/10 Composite Insulation:\u003c\/b\u003e Each of the 4 conductors is insulated with 15 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection. This thinner insulation profile allows for reduced overall cable diameter and easier routing in dense terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a continuous, low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and legislation-compliant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eSubstation Control Networks:\u003c\/b\u003e Transmitting digital or analog low-current signals between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting secondary arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects, SCADA RTU loops, and power monitoring circuits operating near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eNumber of Conductors:\u003c\/b\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eInsulation System:\u003c\/b\u003e 15 mils PE \/ 10 mils PVC (Total 25 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 4-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470063132986,"sku":"SUB18-4SH-15\/10-250","price":326.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470063165754,"sku":"SUB18-4SH-15\/10-500","price":647.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470063198522,"sku":"SUB18-4SH-15\/10-1K","price":1287.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470063231290,"sku":"SUB18-4SH-15\/10-FT","price":1.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-4-shielded-substation-control-cable-15-10-pe-pvc.jpg?v=1779141399"},{"product_id":"10-2-shielded-substation-control-cable-20-10-pe-pvc","title":"10\/2 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 2-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/2 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Transmitting digital or analog signals between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 2-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470063788346,"sku":"SUB10-2SH-20\/10-250","price":547.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470063821114,"sku":"SUB10-2SH-20\/10-500","price":1088.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470063853882,"sku":"SUB10-2SH-20\/10-1K","price":2165.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470063886650,"sku":"SUB10-2SH-20\/10-FT","price":2.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-2-shielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779141209"},{"product_id":"10-4-shielded-substation-control-cable-20-10-pe-pvc","title":"10\/4 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 4-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding multi-circuit supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/4 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 4 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Consolidating multiple digital or analog signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 4-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470063919418,"sku":"SUB10-4SH-20\/10-250","price":564.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470063952186,"sku":"SUB10-4SH-20\/10-500","price":1123.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470063984954,"sku":"SUB10-4SH-20\/10-1K","price":2233.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470064017722,"sku":"SUB10-4SH-20\/10-FT","price":2.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-4-shielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779141271"},{"product_id":"10-5-shielded-substation-control-cable-20-10-pe-pvc","title":"10\/5 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 5-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding multi-circuit supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/5 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 5 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Consolidating multiple digital or analog signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 5-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470064050490,"sku":"SUB10-5SH-20\/10-250","price":596.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470064083258,"sku":"SUB10-5SH-20\/10-500","price":1186.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470064116026,"sku":"SUB10-5SH-20\/10-1K","price":2360.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470064148794,"sku":"SUB10-5SH-20\/10-FT","price":2.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-5-shielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779141126"},{"product_id":"10-9-shielded-substation-control-cable-20-10-pe-pvc","title":"10\/9 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 9-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding multi-circuit supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/9 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 9 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Consolidating multiple digital or analog signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 9\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 9-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470064181562,"sku":"SUB10-9SH-20\/10-250","price":653.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470064214330,"sku":"SUB10-9SH-20\/10-500","price":1299.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470064247098,"sku":"SUB10-9SH-20\/10-1K","price":2584.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470064279866,"sku":"SUB10-9SH-20\/10-FT","price":2.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-9C-shielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779141049"},{"product_id":"10-12-shielded-substation-control-cable-20-10-pe-pvc","title":"10\/12 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 12-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding multi-circuit supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/12 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Consolidating multiple digital or analog signal paths between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets into a single run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting arrays of current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run multi-point data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA Method 1 (Color Code Sequence)\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e\u003c\/b\u003e\n\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\u003ci data-path-to-node=\"7,11,0\" data-index-in-node=\"26\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003c\/i\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. Verify grounding specs against the specific utility engineering layout.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 12-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470064673082,"sku":"SUB10-12SH-20\/10-250","price":688.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470064705850,"sku":"SUB10-12SH-20\/10-500","price":1368.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470064738618,"sku":"SUB10-12SH-20\/10-1K","price":2721.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470064771386,"sku":"SUB10-12SH-20\/10-FT","price":2.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-12-shielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779140995"},{"product_id":"8-3-shielded-substation-control-cable-20-10-pe-pvc","title":"8\/3 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 8 AWG, 3-conductor shielded substation control cable is a heavy-duty utility cable engineered for demanding supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 8\/3 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each conductor is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Transmitting digital or analog signals between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: E 1 (Color Code)\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eConductor 1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eConductor 2:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eConductor 3:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 8 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Utility standards for high-voltage substations (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. Verify grounding specs against the specific utility engineering layout.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 8 AWG \/ 3-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470064542010,"sku":"SUB8-3SH-45\/15-250","price":776.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470064574778,"sku":"SUB8-3SH-45\/15-500","price":1544.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470064607546,"sku":"SUB8-3SH-45\/15-1K","price":3072.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470064640314,"sku":"SUB8-3SH-45\/15-FT","price":3.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/8-3-shielded-substation-control-cable-20-10-pe-pvc-utility.jpg?v=1779140925"},{"product_id":"2-1-shielded-substation-control-cable-20-10-pe-pvc","title":"2\/1 Shielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 2 AWG, 1-conductor (single conductor) shielded substation control cable is a heavy-duty utility cable engineered for demanding supervisory control, metering, and protective relaying circuits. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system and a high-performance copper tape shield. This construction provides exceptional dielectric strength and critical shielding against transient voltage surges and electromagnetic interference (EMI) typical in high-voltage substation switchyards.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 2\/1 Shielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e The conductor is insulated with 20 mils of Natural Polyethylene (PE) for primary electrical strength and low dielectric loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for color coding and robust physical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eSuperior EMI\/RFI Shielding:\u003c\/b\u003e Wrapped with a helically applied 5-mil bare copper tape shield (minimum 20% overlap). This provides a low-resistance path to ground, suppressing dangerous high-frequency transients and induced magnetic\/electrostatic currents caused by breaker operations and inductive switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. This enables versatile installation paths—approved for wet or dry conditions, direct burial, open air, cable trays, troughs, or embedded conduit networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eCorrosion-Resistant Base:\u003c\/b\u003e Features a premium Class B concentrically stranded bare copper conductor conforming to ASTM B3 and B8, balancing structural stability with industrial installation flexibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation Control Networks:\u003c\/b\u003e Transmitting digital or analog signals between control houses, switchyard equipment, marshalling kiosks, and terminal cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eProtective Relaying \u0026amp; Telemetry:\u003c\/b\u003e Connecting current transformers (CTs), potential transformers (PTs), and circuit breaker trip circuits where false signals from ambient electrical noise must be prevented.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eUtility Metering \u0026amp; Monitoring:\u003c\/b\u003e Long-run data interconnects and power monitoring loops operating in high thermal or electrical stress zones near extra-high-voltage (EHV) busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Heavy Duty Control:\u003c\/b\u003e General-purpose, low-impedance control functions in power generation plants, chemical refineries, and heavy manufacturing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 2 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 1 (Single Conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e 0.005\" (5 mil) Helical Bare Copper Tape Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V (Available up to 1000V for heavy inductive breaking profiles)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-path-to-node=\"7,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,8,0\"\u003e\u003cb data-path-to-node=\"7,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"8\"\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Rocketing high-voltage substation standards (especially 138 kV and above) often require copper tape shields to be grounded at multiple points (at minimum both ends) to mitigate high-frequency transient voltages produced by switchyard arcs, rather than grounding at only the source end to prevent low-frequency ground loops. Verify grounding specs against the specific utility engineering layout.\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 2 AWG \/ 1-Conductor Shielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"10\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"11\"\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53470064804154,"sku":"SUB2-1SH-45\/30-250","price":1074.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53470064836922,"sku":"SUB2-1SH-45\/30-500","price":2137.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53470064869690,"sku":"SUB2-1SH-45\/30-1K","price":4251.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53470064902458,"sku":"SUB2-1SH-45\/30-FT","price":4.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2-1-shielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779140856"},{"product_id":"18-12-unshielded-substation-control-cable-15-10-pe-pvc","title":"18\/12 Unshielded Substation Control Cable - 15\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 18 AWG, 12-conductor unshielded substation control cable is a multi-circuit cable engineered for utility and industrial environments requiring precise signal and lower-current control mapping. Built to strict ICEA standards, it features a specialized composite 15\/10 PE\/PVC insulation system designed for smaller gauge profiles. Because it is unshielded, it is optimized for multi-point secondary control loops and dense terminal cabinet routing where high-frequency electromagnetic interference (EMI) shielding is not required, offering excellent flexibility and an easy termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 18\/12 Unshielded 15\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eSpecialized 15\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 15 mils of Natural Polyethylene (PE) for dependable dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape or braided shield, this multi-conductor cable features an exceptionally small overall outer diameter and tight bending radius, making it incredibly easy to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHighly Flexible Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, balancing durable service life with high flexibility for tight terminal block terminations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSecondary Control Circuits:\u003c\/b\u003e Consolidating lower-current monitoring, signaling, and control circuits from auxiliary panels, annunciators, and status indicator lights to main switchgear blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Control Panels:\u003c\/b\u003e Routing interlocking control networks, remote circuit breaker position indicators, and auxiliary alarm lines within the substation control house.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for low-current solenoid controls, status relays, and automated sequencing arrays where multiple discrete voltage pathways must span long physical distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Automation \u0026amp; Control:\u003c\/b\u003e General-purpose multi-conductor control loops and machinery automation links in power generation stations, wastewater treatment facilities, and industrial manufacturing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\" id=\"p-rc_dcb089f23fdd7943-342\"\u003e\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 18 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 15 mils PE \/ 10 mils PVC (Total 25 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Note that this cable utilizes a \u003cb data-path-to-node=\"11\" data-index-in-node=\"48\"\u003e15\/10 insulation profile\u003c\/b\u003e (25 mils total) rather than the 20\/10 profile common in heavier 14 AWG to 10 AWG substation cables, reflecting its smaller 18 AWG conductor base. Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"239\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 18 AWG \/ 12-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488712614202,"sku":"SUB18-12-15\/10-250","price":313.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488712646970,"sku":"SUB18-12-15\/10-500","price":623.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488712679738,"sku":"SUB18-12-15\/10-1K","price":1239.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488712712506,"sku":"SUB18-12-15\/10-FT","price":1.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/18-12-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887776"},{"product_id":"14-4-unshielded-substation-control-cable-20-10-pe-pvc","title":"14\/4 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 14 AWG, 4-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 14\/4 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 4 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14 AWG \/ 4-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488712745274,"sku":"SUB14-4-20\/10-250","price":806.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488712778042,"sku":"SUB14-4-20\/10-500","price":1603.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488712810810,"sku":"SUB14-4-20\/10-1K","price":3189.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488712843578,"sku":"SUB14-4-20\/10-FT","price":3.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/14-4-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887683"},{"product_id":"14-7-unshielded-substation-control-cable-20-10-pe-pvc","title":"14\/7 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 14 AWG, 7-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 14\/7 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 7 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e White with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14 AWG \/ 7-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488712909114,"sku":"SUB14-7-20\/10-250","price":971.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488712941882,"sku":"SUB14-7-20\/10-500","price":1931.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488712974650,"sku":"SUB14-7-20\/10-1K","price":3842.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488713007418,"sku":"SUB14-7-20\/10-FT","price":3.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/14-7-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887721"},{"product_id":"14-12-unshielded-substation-control-cable-20-10-pe-pvc","title":"14\/12 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 14 AWG, 12-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 14\/12 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\" id=\"p-rc_ac61046444264bd6-318\"\u003e\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 14 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 14 AWG \/ 12-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488713040186,"sku":"SUB14-12-20\/10-250","price":1003.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488713072954,"sku":"SUB14-12-20\/10-500","price":1995.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488713105722,"sku":"SUB14-12-20\/10-1K","price":3969.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488713138490,"sku":"SUB14-12-20\/10-FT","price":4.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/14-12-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887834"},{"product_id":"12-2-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/2 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/2 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 2-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488713367866,"sku":"SUB12-2-20\/10-250","price":921.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488713400634,"sku":"SUB12-2-20\/10-500","price":1833.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488713433402,"sku":"SUB12-2-20\/10-1K","price":3647.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488713466170,"sku":"SUB12-2-20\/10-FT","price":3.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-2-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887495"},{"product_id":"12-3-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/3 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 3-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/3 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 3-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488713597242,"sku":"SUB12-3-20\/10-250","price":953.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488713630010,"sku":"SUB12-3-20\/10-500","price":1897.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488713662778,"sku":"SUB12-3-20\/10-1K","price":3774.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488713695546,"sku":"SUB12-3-20\/10-FT","price":3.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-3-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887531"},{"product_id":"12-7-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/7 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 7-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/7 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 7 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e White with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 7-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488713892154,"sku":"SUB12-7-20\/10-250","price":1020.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488713924922,"sku":"SUB12-7-20\/10-500","price":2029.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488713957690,"sku":"SUB12-7-20\/10-1K","price":4037.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488713990458,"sku":"SUB12-7-20\/10-FT","price":4.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-7-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887626"},{"product_id":"12-4-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/4 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 4-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/4 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 4 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 4-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488713728314,"sku":"SUB12-4-20\/10-250","price":983.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488713761082,"sku":"SUB12-4-20\/10-500","price":1956.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488713793850,"sku":"SUB12-4-20\/10-1K","price":3891.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488713826618,"sku":"SUB12-4-20\/10-FT","price":3.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-4-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887580"},{"product_id":"12-8-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/8 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 8-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/8 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 8 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e White with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-path-to-node=\"7,7,0\" data-index-in-node=\"0\"\u003e8:\u003c\/b\u003e Red with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 8-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488714252602,"sku":"SUB12-8-20\/10-250","price":1052.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488714285370,"sku":"SUB12-8-20\/10-500","price":2093.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488714318138,"sku":"SUB12-8-20\/10-1K","price":4164.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488714350906,"sku":"SUB12-8-20\/10-FT","price":4.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-8-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887387"},{"product_id":"12-9-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/9 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 12 AWG, 9-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/9 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 9 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e White with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,7,0\"\u003e\u003cb data-path-to-node=\"7,7,0\" data-index-in-node=\"0\"\u003e8:\u003c\/b\u003e Red with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,8,0\"\u003e\u003cb data-path-to-node=\"7,8,0\" data-index-in-node=\"0\"\u003e9:\u003c\/b\u003e Green with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 9\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 9-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488714383674,"sku":"SUB12-9-20\/10-250","price":1163.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488714416442,"sku":"SUB12-9-20\/10-500","price":2313.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488714449210,"sku":"SUB12-9-20\/10-1K","price":4602.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488714481978,"sku":"SUB12-9-20\/10-FT","price":4.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-9-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887256"},{"product_id":"12-12-unshielded-substation-control-cable-20-10-pe-pvc","title":"12\/12 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"1\"\u003eThis 12 AWG, 12-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 12\/12 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp id=\"p-rc_cd09c668e761e0e5-294\" data-path-to-node=\"7,0,0\"\u003e\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eConductor Size:\u003c\/b\u003e 12 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-index-in-node=\"36\" data-path-to-node=\"11\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eCABLE TYPE:\u003c\/b\u003e 12 AWG \/ 12-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488714547514,"sku":"SUB12-12-20\/10-250","price":1150.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488714580282,"sku":"SUB12-12-20\/10-500","price":2289.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488714613050,"sku":"SUB12-12-20\/10-1K","price":4554.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488714645818,"sku":"SUB12-12-20\/10-FT","price":4.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/12-12-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887428"},{"product_id":"10-2-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/2 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/2 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 2-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488714776890,"sku":"SUB10-2-20\/10-250","price":981.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488714809658,"sku":"SUB10-2-20\/10-500","price":1951.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488714842426,"sku":"SUB10-2-20\/10-1K","price":3881.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488714875194,"sku":"SUB10-2-20\/10-FT","price":3.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-2-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887309"},{"product_id":"10-3-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/3 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 3-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/3 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 3-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488715071802,"sku":"SUB10-3-20\/10-250","price":1003.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488715104570,"sku":"SUB10-3-20\/10-500","price":1995.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488715137338,"sku":"SUB10-3-20\/10-1K","price":3969.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488715170106,"sku":"SUB10-3-20\/10-FT","price":4.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-3-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887199"},{"product_id":"10-4-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/4 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 4-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/4 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 4 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 4-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488715333946,"sku":"SUB10-4-20\/10-250","price":1052.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488715366714,"sku":"SUB10-4-20\/10-500","price":2093.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488715399482,"sku":"SUB10-4-20\/10-1K","price":4164.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488715432250,"sku":"SUB10-4-20\/10-FT","price":4.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-4-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887154"},{"product_id":"10-7-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/7 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 7-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/7 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 7 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003e6:\u003c\/b\u003e Blue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,6,0\"\u003e\u003cb data-path-to-node=\"7,6,0\" data-index-in-node=\"0\"\u003e7:\u003c\/b\u003e White with Black Stripe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 7\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e \u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 7-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488715596090,"sku":"SUB10-7-20\/10-250","price":1158.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488715628858,"sku":"SUB10-7-20\/10-500","price":2303.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488715661626,"sku":"SUB10-7-20\/10-1K","price":4583.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488715694394,"sku":"SUB10-7-20\/10-FT","price":4.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-7-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779887105"},{"product_id":"10-5-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/5 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 5-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/5 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 5 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003e4:\u003c\/b\u003e Green\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003e5:\u003c\/b\u003e Orange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 5\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"11\"\u003e \u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 5-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488715202874,"sku":"SUB10-5-20\/10-250","price":1084.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488715235642,"sku":"SUB10-5-20\/10-500","price":2156.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488715268410,"sku":"SUB10-5-20\/10-1K","price":4290.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488715301178,"sku":"SUB10-5-20\/10-FT","price":4.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-5-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779841528"},{"product_id":"10-9-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/9 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 9-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/9 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 9 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 9\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 9-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488716022074,"sku":"SUB10-9-20\/10-250","price":1217.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488716054842,"sku":"SUB10-9-20\/10-500","price":2421.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488716087610,"sku":"SUB10-9-20\/10-1K","price":4817.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488716120378,"sku":"SUB10-9-20\/10-FT","price":4.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-9-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779841416"},{"product_id":"10-12-unshielded-substation-control-cable-20-10-pe-pvc","title":"10\/12 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 10 AWG, 12-conductor unshielded substation control cable is a heavy-duty multi-circuit cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-density control circuits, multi-point secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 10\/12 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 12 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this multi-conductor cable features a smaller overall outer diameter and tighter bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and complex terminal enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for multi-circuit control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Consolidating multiple circuits from battery banks, chargers, and main DC distribution panels to circuit breaker trip coils, alarm panels, and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power \u0026amp; Control:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power and control circuits to transformer cooling fans, motorized disconnect switches, and panel heating elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eMulti-Circuit Control Loops:\u003c\/b\u003e Ideal for motor-operated switches (MOS), high-current valve actuators, and interlocking networks where multiple voltage signals must be routed across long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose multi-conductor control loops and heavy machinery automation in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\" id=\"p-rc_6e64824ba128429c-270\"\u003e\u003cmeta charset=\"utf-8\"\u003eBlack, White, Red, Green, Orange, Blue, White\/Black, Red\/Black, Green\/Black, Orange\/Black, Blue\/Black, Black\/White\u003c\/p\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003cdiv class=\"source-inline-chip-container ng-star-inserted\"\u003e\n\u003c!----\u003e\u003c!----\u003e\n\u003c\/div\u003e\n\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\u003c!----\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 10 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #4 Green or #2 White conductors as active control legs if your facility reserves those colors exclusively for ground and neutral paths.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 10 AWG \/ 12-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488716185914,"sku":"SUB10-12-20\/10-250","price":1298.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488716218682,"sku":"SUB10-12-20\/10-500","price":2583.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488716251450,"sku":"SUB10-12-20\/10-1K","price":5139.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488716284218,"sku":"SUB10-12-20\/10-FT","price":5.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/10-12-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779841290"},{"product_id":"8-2-unshielded-substation-control-cable-20-10-pe-pvc","title":"8\/2 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 8 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 8\/2 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eHeavy Control Circuits:\u003c\/b\u003e Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 8 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 8 AWG \/ 2-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488716349754,"sku":"SUB8-2-45\/15-250","price":1052.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488716382522,"sku":"SUB8-2-45\/15-500","price":2093.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488716415290,"sku":"SUB8-2-45\/15-1K","price":4164.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488716448058,"sku":"SUB8-2-45\/15-FT","price":4.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/8-2-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779841013"},{"product_id":"8-3-unshielded-substation-control-cable-20-10-pe-pvc","title":"8\/3 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 8 AWG, 3-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 8\/3 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eHeavy Control Circuits:\u003c\/b\u003e Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 8 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 8 AWG \/ 3-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488716513594,"sku":"SUB8-3-45\/15-250","price":1114.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488716546362,"sku":"SUB8-3-45\/15-500","price":2215.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488716579130,"sku":"SUB8-3-45\/15-1K","price":4407.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488716611898,"sku":"SUB8-3-45\/15-FT","price":4.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/8-3-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779840842"},{"product_id":"6-2-unshielded-substation-control-cable-20-10-pe-pvc","title":"6\/2 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 6 AWG, 2-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 6\/2 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 2 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eHeavy Control Circuits:\u003c\/b\u003e Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 6 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 6 AWG \/ 2-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488716874042,"sku":"SUB6-2-45\/25-250","price":1082.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488716906810,"sku":"SUB6-2-45\/25-500","price":2152.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488716939578,"sku":"SUB6-2-45\/25-1K","price":4281.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488716972346,"sku":"SUB6-2-45\/25-FT","price":4.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/6-2-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779840730"},{"product_id":"6-3-unshielded-substation-control-cable-20-10-pe-pvc","title":"6\/3 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThis 6 AWG, 3-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 6\/3 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-path-to-node=\"3,0,0\" data-index-in-node=\"0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-path-to-node=\"3,1,0\" data-index-in-node=\"0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-path-to-node=\"3,2,0\" data-index-in-node=\"0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-path-to-node=\"3,3,0\" data-index-in-node=\"0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eStation Service Power:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eHeavy Control Circuits:\u003c\/b\u003e Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-path-to-node=\"9,0,0\" data-index-in-node=\"0\"\u003eConductor Size:\u003c\/b\u003e 6 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-path-to-node=\"9,1,0\" data-index-in-node=\"0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-path-to-node=\"9,2,0\" data-index-in-node=\"0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-path-to-node=\"9,3,0\" data-index-in-node=\"0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-path-to-node=\"9,4,0\" data-index-in-node=\"0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-path-to-node=\"9,5,0\" data-index-in-node=\"0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-path-to-node=\"9,6,0\" data-index-in-node=\"0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-path-to-node=\"9,7,0\" data-index-in-node=\"0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-path-to-node=\"9,8,0\" data-index-in-node=\"0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-path-to-node=\"11\" data-index-in-node=\"36\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-path-to-node=\"12\" data-index-in-node=\"0\"\u003eCABLE TYPE:\u003c\/b\u003e 6 AWG \/ 3-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-path-to-node=\"14\" data-index-in-node=\"0\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment.\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488717103418,"sku":"SUB6-3-45\/25-250","price":1180.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488717136186,"sku":"SUB6-3-45\/25-500","price":2348.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488717168954,"sku":"SUB6-3-45\/25-1K","price":4671.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488717201722,"sku":"SUB6-3-45\/25-FT","price":4.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/6-3-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779840623"},{"product_id":"4-3-unshielded-substation-control-cable-20-10-pe-pvc","title":"4\/3 Unshielded Substation Control Cable - 20\/10 PE\/PVC","description":"\u003cp data-path-to-node=\"1\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"1\"\u003eThis 4 AWG, 3-conductor unshielded substation control cable is a heavy-duty power and control cable engineered for demanding utility and industrial environments. Built to strict ICEA S-73-532 standards, it features a composite 20\/10 PE\/PVC insulation system. Because it is unshielded, it is optimized for high-current control circuits, secondary power feeds, and DC distribution networks where high-frequency electromagnetic interference (EMI) shielding is not required, offering greater flexibility and a simplified termination process.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch4 data-path-to-node=\"2\"\u003eKey Features of 4\/3 Unshielded 20\/10 Substation Cable\u003c\/h4\u003e\n\u003cul data-path-to-node=\"3\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,0,0\"\u003eHeavy-Duty 20\/10 Composite Insulation:\u003c\/b\u003e Each of the 3 conductors is insulated with 20 mils of Natural Polyethylene (PE) for primary dielectric strength and low electrical loss, paired with a 10 mil Polyvinyl Chloride (PVC) outer skin layer for robust physical protection and color identification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,1,0\"\u003eUnshielded Optimization:\u003c\/b\u003e Without the added bulk and rigidity of a copper tape shield, this cable features a smaller bending radius, making it significantly easier to pull through congested conduit runs, cable trays, and tight enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,2,0\"\u003eUtility-Grade Durability:\u003c\/b\u003e Protected by a rugged, flame-retardant, and sunlight-resistant black PVC jacket. It is fully approved for versatile installation paths, including wet or dry conditions, direct burial, open air, cable troughs, or embedded duct banks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"3,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"3,3,0\"\u003eHigh-Ampacity Conductor Base:\u003c\/b\u003e Features premium Class B concentrically stranded bare copper conductors conforming to ASTM B3 and B8, offering excellent current capacity for heavy control functions and station service power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"4\"\u003eCommon Applications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eSubstation DC Distribution:\u003c\/b\u003e Connecting battery banks, chargers, and main DC distribution panels to circuit breaker trip coils and switchgear control busses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eStation Service Power:\u003c\/b\u003e Providing reliable auxiliary AC\/DC power to transformer cooling fans, pump motors, and panel heating elements within the switchyard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eHeavy Control Circuits:\u003c\/b\u003e Ideal for motor-operated switches (MOS), disconnect switches, and high-current valve actuators where voltage drop must be minimized over long distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eIndustrial Power Distribution:\u003c\/b\u003e General-purpose power loops and heavy machinery control in power generation stations, wastewater treatment facilities, and heavy industrial plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"6\"\u003eConductor Identification: ICEA E-1 Color Code Sequence\u003c\/h4\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003e1:\u003c\/b\u003e Black\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003e2:\u003c\/b\u003e White\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003e3:\u003c\/b\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-path-to-node=\"8\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul data-path-to-node=\"9\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,0,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,0,0\"\u003eConductor Size:\u003c\/b\u003e 4 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,1,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,1,0\"\u003eNumber of Conductors:\u003c\/b\u003e 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,2,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,2,0\"\u003eConductor Material:\u003c\/b\u003e Bare Soft Annealed Copper (Class B Stranded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,3,0\"\u003eInsulation System:\u003c\/b\u003e 20 mils PE \/ 10 mils PVC (Total 30 mils per conductor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,4,0\"\u003eShielding:\u003c\/b\u003e None (Unshielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,5,0\"\u003eJacket:\u003c\/b\u003e Flame-Retardant, Moisture- \u0026amp; Sunlight-Resistant Black PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,6,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,6,0\"\u003eVoltage Rating:\u003c\/b\u003e 600V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,7,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,7,0\"\u003eTemperature Rating:\u003c\/b\u003e 75°C Wet or Dry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"9,8,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"9,8,0\"\u003eCompliance Standards:\u003c\/b\u003e ICEA S-73-532 \/ NEMA WC 57, ASTM B3 \u0026amp; B8, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-path-to-node=\"10\"\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"11\"\u003eTechnical Note:\u003c\/b\u003e Since this cable is \u003cb data-index-in-node=\"36\" data-path-to-node=\"11\"\u003eunshielded\u003c\/b\u003e, it should not be placed in the same tray or conduit as sensitive, low-voltage microprocessor-based communication lines or analog sensor loops (SCADA inputs). For high-voltage switchyards prone to severe transient switching arcs, ensure that this cable's routing complies with appropriate physical separation distances to prevent capacitive or inductive coupling onto adjacent signal lines. When implementing the E-1 color code, ensure field technicians cross-reference terminal blocks to avoid using the #2 White conductor as an active control leg if your facility reserves that color exclusively for system neutrals.\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"12\"\u003eCABLE TYPE:\u003c\/b\u003e 4 AWG \/ 3-Conductor Unshielded Substation Control Cable\u003c\/p\u003e\n\u003cp data-path-to-node=\"12\"\u003e \u003c\/p\u003e\n\u003chr data-path-to-node=\"13\"\u003e\n\u003cp data-path-to-node=\"14\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"14\"\u003eDISCLAIMER:\u003c\/b\u003e The technical information provided is for general reference only. Utility substation construction guidelines are rigorous and highly specific. Always consult with a licensed power utility electrical engineer and comply with ICEA, NEMA, and National Electrical Safety Code (NESC) regulations prior to system deployment\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53488717234490,"sku":"SUB4-3-45\/25-250","price":1094.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53488717267258,"sku":"SUB4-3-45\/25-500","price":2176.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53488717300026,"sku":"SUB4-3-45\/25-1K","price":4329.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53488717332794,"sku":"SUB4-3-45\/25-FT","price":4.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/4-3-unshielded-substation-control-cable-20-10-pe-pvc.jpg?v=1779840673"}],"url":"https:\/\/www.wireamerica.com\/collections\/substation-control-cable.oembed","provider":"Wire America ","version":"1.0","type":"link"}