{"title":"COPPER MV-105 5kV-35kV","description":"\u003cp\u003e\u003cstrong\u003eCopper MV-105 Cable\u003c\/strong\u003e is a specialized, medium-voltage \u003cstrong\u003e(5kV to 35kV) \u003c\/strong\u003eelectrical cable designed for high-capacity power distribution, distinguished by its superior 105°C continuous operating temperature rating. This high thermal rating allows it to handle higher ampacity loads than standard MV-90 cable. Built with robust XLPE or EPR insulation and crucial metallic shielding, MV-105 provides excellent resistance to electrical stress, moisture, oil, and UV radiation. It is widely used in demanding environments like industrial plants for main feeder lines, utility distribution, and for reliably powering large industrial motors in both outdoor and direct burial installations. \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eRead our \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003e\u003ca title=\"Copper MV-105 Power Cable Buyers Guide | Wire America\" href=\"https:\/\/wireamerica.com\/blogs\/news\/copper-mv-105-buying-guide-5kv-35kv-medium-voltage-power\"\u003eCopper MV-105 Buyers Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eNeed a quote? \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eCall us at:\u003c\/span\u003e 833-268-8644 \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(64, 64, 64);\"\u003eor e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003email: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003esales@wireamerica.com\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"1-0-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"1\/0 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e200 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 220 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000433439034,"sku":"MV105CU-5KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000433471802,"sku":"MV105CU-5KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000433504570,"sku":"MV105CU-5KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000433537338,"sku":"MV105CU-5KEPR-1\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000433570106,"sku":"MV105CU-5KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"6-awg-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"6 AWG 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 83 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e93 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e90 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e97 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000433930554,"sku":"MV105CU-5KEPR-6-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000433963322,"sku":"MV105CU-5KEPR-6-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000433996090,"sku":"MV105CU-5KEPR-6-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000434028858,"sku":"MV105CU-5KEPR-6-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000434061626,"sku":"MV105CU-5KEPR-6-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"4-awg-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"4 AWG 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 110 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e120 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e115 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e125 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000433766714,"sku":"MV105CU-5KEPR-4-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000433799482,"sku":"MV105CU-5KEPR-4-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000433832250,"sku":"MV105CU-5KEPR-4-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000433865018,"sku":"MV105CU-5KEPR-4-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000433897786,"sku":"MV105CU-5KEPR-4-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"2-awg-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"2 AWG 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e155 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000433602874,"sku":"MV105CU-5KEPR-2-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000433635642,"sku":"MV105CU-5KEPR-2-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000433668410,"sku":"MV105CU-5KEPR-2-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000433701178,"sku":"MV105CU-5KEPR-2-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000433733946,"sku":"MV105CU-5KEPR-2-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"2-0-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"2\/0 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 225 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e255 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e230 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 245 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 225 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 250 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000434684218,"sku":"MV105CU-5KEPR-2\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000434716986,"sku":"MV105CU-5KEPR-2\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000434749754,"sku":"MV105CU-5KEPR-2\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000434782522,"sku":"MV105CU-5KEPR-2\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000434815290,"sku":"MV105CU-5KEPR-2\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"4-0-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"4\/0 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 295 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e330 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e230 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 245 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 300 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 335 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000434848058,"sku":"MV105CU-5KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000434880826,"sku":"MV105CU-5KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000434913594,"sku":"MV105CU-5KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000434946362,"sku":"MV105CU-5KEPR-4\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000434979130,"sku":"MV105CU-5KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"250-mcm-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"250 MCM 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 330 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e365 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e325 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 345 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 335 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 370 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000435044666,"sku":"MV105CU-5KEPR-250-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000435077434,"sku":"MV105CU-5KEPR-250-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000435110202,"sku":"MV105CU-5KEPR-250-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000435142970,"sku":"MV105CU-5KEPR-250-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000435175738,"sku":"MV105CU-5KEPR-250-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"350-mcm-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"350 MCM 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 395 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e440 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e390 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 415 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 415 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 460 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000435241274,"sku":"MV105CU-5KEPR-350-250","price":5044.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000435274042,"sku":"MV105CU-5KEPR-350-500","price":10036.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000435306810,"sku":"MV105CU-5KEPR-350-1K","price":19237.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000435339578,"sku":"MV105CU-5KEPR-350-2500","price":48000.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000435372346,"sku":"MV105CU-5KEPR-350-FT","price":20.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"500-mcm-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"500 MCM 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 480 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e535 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e465 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 500 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 515 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 575 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000435863866,"sku":"MV105CU-5KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000435896634,"sku":"MV105CU-5KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000435929402,"sku":"MV105CU-5KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000435962170,"sku":"MV105CU-5KEPR-500-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000435994938,"sku":"MV105CU-5KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"750-mcm-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"750 MCM 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 585 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e655 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e565 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 610 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 665 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 745 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000436060474,"sku":"MV105CU-5KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000436093242,"sku":"MV105CU-5KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000436126010,"sku":"MV105CU-5KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000436158778,"sku":"MV105CU-5KEPR-750-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000436191546,"sku":"MV105CU-5KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"1000-mcm-mv-105-epr-pvc-copper-tape-shield-5kv-8kv","title":"1000 MCM 5kV\/8kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 5KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 5kV in ungrounded applications and 8kV for grounded applications.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 675 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e755 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e640 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C -\u003cstrong\u003e 690 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 795 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 890 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52000436257082,"sku":"MV105CU-5KEPR-1000-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52000436289850,"sku":"MV105CU-5KEPR-1000-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52000436322618,"sku":"MV105CU-5KEPR-1000-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52000436355386,"sku":"MV105CU-5KEPR-1000-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52000436388154,"sku":"MV105CU-5KEPR-1000-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"1-0-mv-105-epr-pvc-copper-tape-shield-35kv","title":"1\/0 35kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield, 100%","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e200 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C\u003cstrong\u003e \u003c\/strong\u003e-\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 220 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981984989498,"sku":"MV105CU-35KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981985022266,"sku":"MV105CU-35KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981985055034,"sku":"MV105CU-35KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":51981985087802,"sku":"MV105CU-35KEPR-1\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981985120570,"sku":"MV105CU-35KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/wa-product-industrial-detail-2-AWG-MV-105_80e6cf28-33e1-42af-882f-80440fbb32ed.png?v=1760026668"},{"product_id":"4-0-mv-105-epr-pvc-copper-tape-shield-35kv","title":"4\/0 35kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield, 100%","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 295 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e330 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e295 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e315 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C\u003cstrong\u003e \u003c\/strong\u003e-\u003cstrong\u003e 295 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 335 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981985317178,"sku":"MV105CU-35KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981985349946,"sku":"MV105CU-35KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981985382714,"sku":"MV105CU-35KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":51981985415482,"sku":"MV105CU-35KEPR-4\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981985448250,"sku":"MV105CU-35KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/wa-product-industrial-detail-2-AWG-MV-105_d9614dda-3791-4abb-ac49-c8d9dcc58240.png?v=1760026668"},{"product_id":"350-mcm-mv-105-epr-pvc-copper-tape-shield-35kv","title":"350 MCM 35kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield, 100%","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 395 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e440 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e390 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e415 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C\u003cstrong\u003e \u003c\/strong\u003e-\u003cstrong\u003e 410 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 455 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981985481018,"sku":"MV105CU-35KEPR-350-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981985513786,"sku":"MV105CU-35KEPR-350-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981985546554,"sku":"MV105CU-35KEPR-350-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":51981985579322,"sku":"MV105CU-35KEPR-350-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981985612090,"sku":"MV105CU-35KEPR-350-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/wa-product-industrial-detail-2-AWG-MV-105_8bbf9a75-9751-4fe5-b1e4-e90d3dbf6708.png?v=1760026668"},{"product_id":"500-mcm-mv-105-epr-pvc-copper-tape-shield-35kv","title":"500 MCM 35kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield, 100%","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 480 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e535 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e465 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e500 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C\u003cstrong\u003e \u003c\/strong\u003e-\u003cstrong\u003e 510 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 565 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981985644858,"sku":"MV105CU-35KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981985677626,"sku":"MV105CU-35KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981985710394,"sku":"MV105CU-35KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":51981985743162,"sku":"MV105CU-35KEPR-500-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981985775930,"sku":"MV105CU-35KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/wa-product-industrial-detail-2-AWG-MV-105_5280e383-acc3-480d-94b2-16aa9aee1491.png?v=1760026669"},{"product_id":"750-mcm-mv-105-epr-pvc-copper-tape-shield-35kv","title":"750 MCM 35kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield, 100%","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 585 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e655 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e565 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e610 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C\u003cstrong\u003e \u003c\/strong\u003e-\u003cstrong\u003e 655 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 730 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981985808698,"sku":"MV105CU-35KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981985841466,"sku":"MV105CU-35KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981985874234,"sku":"MV105CU-35KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":51981985907002,"sku":"MV105CU-35KEPR-750-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981985939770,"sku":"MV105CU-35KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/wa-product-industrial-detail-2-AWG-MV-105_9226ef5b-aee5-45b8-9a52-99912c2bb56b.png?v=1760026668"},{"product_id":"1000-mcm-mv-105-epr-pvc-copper-tape-shield-35kv","title":"1000 MCM 35kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield, 100%","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 675 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e755 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e640 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e690 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C\u003cstrong\u003e \u003c\/strong\u003e-\u003cstrong\u003e 780 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 870 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":51981985972538,"sku":"MV105CU-35KEPR-1000-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":51981986005306,"sku":"MV105CU-35KEPR-1000-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":51981986038074,"sku":"MV105CU-35KEPR-1000-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":51981986070842,"sku":"MV105CU-35KEPR-1000-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":51981986103610,"sku":"MV105CU-35KEPR-1000-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/wa-product-industrial-detail-2-AWG-MV-105_6fd84488-2015-4400-a528-c293bbbd2101.png?v=1760026668"},{"product_id":"2-awg-mv-105-epr-pvc-copper-tape-shield-15kv","title":"2 AWG 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e155 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548650697018,"sku":"MV105CU-15KEPR-2-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548650729786,"sku":"MV105CU-15KEPR-2-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548650762554,"sku":"MV105CU-15KEPR-2-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548650795322,"sku":"MV105CU-15KEPR-2-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548650828090,"sku":"MV105CU-15KEPR-2-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"2-0-mv-105-epr-pvc-copper-tape-shield-15kv","title":"2\/0 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 225 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e255 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e230 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e245 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 225 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 250 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548650860858,"sku":"MV105CU-15KEPR-2\/0-250","price":3145.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548650893626,"sku":"MV105CU-15KEPR-2\/0-500","price":6258.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548650926394,"sku":"MV105CU-15KEPR-2\/0-1K","price":12451.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548650959162,"sku":"MV105CU-15KEPR-2\/0-2500","price":30968.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548650991930,"sku":"MV105CU-15KEPR-2\/0-FT","price":12.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"1-awg-mv-105-epr-pvc-copper-tape-shield-15kv","title":"1 AWG 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 170 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e190 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e175 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e185 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548650533178,"sku":"MV105CU-15KEPR-1-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548650565946,"sku":"MV105CU-15KEPR-1-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548650598714,"sku":"MV105CU-15KEPR-1-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548650631482,"sku":"MV105CU-15KEPR-1-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548650664250,"sku":"MV105CU-15KEPR-1-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"1-0-mv-105-epr-pvc-copper-tape-shield-15kv","title":"1\/0 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e200 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e215 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C\u003cstrong\u003e - 220 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548650369338,"sku":"MV105CU-15KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548650402106,"sku":"MV105CU-15KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548650434874,"sku":"MV105CU-15KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548650467642,"sku":"MV105CU-15KEPR-1\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548650500410,"sku":"MV105CU-15KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"4-0-mv-105-epr-pvc-copper-tape-shield-15kv","title":"4\/0 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 295 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e330 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e295 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e3\u003c\/strong\u003e1\u003cstrong\u003e5 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 300 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 335 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548651778362,"sku":"MV105CU-15KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548651811130,"sku":"MV105CU-15KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548651843898,"sku":"MV105CU-15KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548651876666,"sku":"MV105CU-15KEPR-4\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548651909434,"sku":"MV105CU-15KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"250-mcm-mv-105-epr-pvc-copper-tape-shield-15kv","title":"250 MCM 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 330 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e365 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e325 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e3\u003c\/strong\u003e4\u003cstrong\u003e5 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 335 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C\u003cstrong\u003e - 370 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548651614522,"sku":"MV105CU-15KEPR-250-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548651647290,"sku":"MV105CU-15KEPR-250-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548651680058,"sku":"MV105CU-15KEPR-250-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548651712826,"sku":"MV105CU-15KEPR-250-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548651745594,"sku":"MV105CU-15KEPR-250-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"350-mcm-mv-105-epr-pvc-copper-tape-shield-15kv","title":"350 MCM 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 395 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e440 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e390 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e415 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 415 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 460 Amps\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548651974970,"sku":"MV105CU-15KEPR-350-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548652007738,"sku":"MV105CU-15KEPR-350-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548652040506,"sku":"MV105CU-15KEPR-350-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548652073274,"sku":"MV105CU-15KEPR-350-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548652106042,"sku":"MV105CU-15KEPR-350-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"500-mcm-mv-105-epr-pvc-copper-tape-shield-15kv","title":"500 MCM 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 480 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e535 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e465 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e500 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 515 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 575 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548652138810,"sku":"MV105CU-15KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548652171578,"sku":"MV105CU-15KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548652204346,"sku":"MV105CU-15KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548652237114,"sku":"MV105CU-15KEPR-500-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548652269882,"sku":"MV105CU-15KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"750-mcm-mv-105-epr-pvc-copper-tape-shield-15kv","title":"750 MCM 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 585 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e655 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e565 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e610 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 665 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C - \u003cstrong\u003e745 Amps\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548652564794,"sku":"MV105CU-15KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548652597562,"sku":"MV105CU-15KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548652630330,"sku":"MV105CU-15KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548652663098,"sku":"MV105CU-15KEPR-750-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548652695866,"sku":"MV105CU-15KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"1000-mcm-mv-105-epr-pvc-copper-tape-shield-15kv","title":"1000 MCM 15kV MV-105 Medium Voltage Cable, EPR\/PVC Copper Tape Shield","description":"\u003cp\u003e\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCopper Shielded MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B annealed compact or compressed bare copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 675 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e755 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e640 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e690 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 795 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 890 Amps\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e\u003c\/p\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52548652728634,"sku":"MV105CU-15KEPR-1000-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52548652761402,"sku":"MV105CU-15KEPR-1000-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52548652794170,"sku":"MV105CU-15KEPR-1000-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":52548652826938,"sku":"MV105CU-15KEPR-1000-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52548652859706,"sku":"MV105CU-15KEPR-1000-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_AWG_COPPER_MV-105_EPR_PVC_COPPER_TAPE_SHIELD.jpg?v=1764797198"},{"product_id":"2-awg-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"2 AWG 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #10\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e185 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e160 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e16 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e212 + j49\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e898 + j33\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015390191930,"sku":"PAGMV105-15KEPR-2-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015390224698,"sku":"PAGMV105-15KEPR-2-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015390257466,"sku":"PAGMV105-15KEPR-2-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015390290234,"sku":"PAGMV105-15KEPR-2-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2-AWG-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908518"},{"product_id":"1-0-awg-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"1\/0 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #8\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e240 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e210 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e17 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -  \u003cstrong\u003e134 + j44\u003c\/strong\u003e\u003cbr\u003eZero Seq -  \u003cstrong\u003e763 + j28\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015390617914,"sku":"PAGMV105-15KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015390650682,"sku":"PAGMV105-15KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015390683450,"sku":"PAGMV105-15KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015390716218,"sku":"PAGMV105-15KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/1-0-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908597"},{"product_id":"4-0-awg-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"4\/0 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #7\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e360 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e305 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e19 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -    \u003cstrong\u003e67 + j40\u003c\/strong\u003e\u003cbr\u003eZero Seq -   \u003cstrong\u003e612 + j24\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015390355770,"sku":"PAGMV105-15KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015390388538,"sku":"PAGMV105-15KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015390421306,"sku":"PAGMV105-15KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015390454074,"sku":"PAGMV105-15KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/4-0-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908618"},{"product_id":"2-0-awg-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"2\/0 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #8\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e275 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e235 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e17 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -   \u003cstrong\u003e107 + j43\u003c\/strong\u003e\u003cbr\u003eZero Seq -  \u003cstrong\u003e710 + j27\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015390486842,"sku":"PAGMV105-15KEPR-2\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015390519610,"sku":"PAGMV105-15KEPR-2\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015390552378,"sku":"PAGMV105-15KEPR-2\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015390585146,"sku":"PAGMV105-15KEPR-2\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/2_0-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908452"},{"product_id":"250-mcm-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"250 MCM 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #6\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e400 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e335 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e20 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -  \u003cstrong\u003e 57 + j39\u003c\/strong\u003e\u003cbr\u003eZero Seq -  \u003cstrong\u003e577 + j23\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015391306042,"sku":"PAGMV105-15KEPR-250-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015391338810,"sku":"PAGMV105-15KEPR-250-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015391371578,"sku":"PAGMV105-15KEPR-250-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015391404346,"sku":"PAGMV105-15KEPR-250-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/250-MCM-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908392"},{"product_id":"350-mcm-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"350 MCM 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #6\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e490 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e400 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e22 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -   \u003cstrong\u003e41 + j37\u003c\/strong\u003e\u003cbr\u003eZero Seq -   \u003cstrong\u003e518 + j21\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015391437114,"sku":"PAGMV105-15KEPR-350-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015391469882,"sku":"PAGMV105-15KEPR-350-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015391502650,"sku":"PAGMV105-15KEPR-350-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015391535418,"sku":"PAGMV105-15KEPR-350-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/350-MCM-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908300"},{"product_id":"500-mcm-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"500 MCM 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #5\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e600 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e485 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e24 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -    \u003cstrong\u003e29 + j34\u003c\/strong\u003e\u003cbr\u003eZero Seq -  \u003cstrong\u003e463 + j19\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015391633722,"sku":"PAGMV105-15KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015391666490,"sku":"PAGMV105-15KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015391699258,"sku":"PAGMV105-15KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015391732026,"sku":"PAGMV105-15KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/500-MCM-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908348"},{"product_id":"750-mcm-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"750 MCM 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #4\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e745 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e585 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e26 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -  \u003cstrong\u003e 20 + j33\u003c\/strong\u003e\u003cbr\u003eZero Seq -   \u003cstrong\u003e401 + j17\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015391764794,"sku":"PAGMV105-15KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015391797562,"sku":"PAGMV105-15KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015391830330,"sku":"PAGMV105-15KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015391863098,"sku":"PAGMV105-15KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/750-MCM-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908241"},{"product_id":"1000-mcm-3c-15kv-133-prysmian-airguard-mv-105-cable","title":"1000 MCM 3C Prysmian Airguard™ 15kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #3\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e860 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e660 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e30 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003c\/strong\u003e\u003cbr\u003ePos\/Neg Seq -   \u003cstrong\u003e16 + j32\u003c\/strong\u003e\u003cbr\u003eZero Seq -  \u003cstrong\u003e361 + j16\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53015392387386,"sku":"PAGMV105-15KEPR-1000-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53015392420154,"sku":"PAGMV105-15KEPR-1000-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53015392452922,"sku":"PAGMV105-15KEPR-1000-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53015392485690,"sku":"PAGMV105-15KEPR-1000-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/1000-MCM-3C-Prysmian-Airguard-15kV-MV-105.jpg?v=1770908179"},{"product_id":"4-0-awg-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"4\/0 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #7\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e360 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e305 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e16 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e  67 + j35\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 752 + j19\u003c\/strong\u003e\u003cbr\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036389368122,"sku":"PAGMV105-5KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036389400890,"sku":"PAGMV105-5KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036389433658,"sku":"PAGMV105-5KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036389466426,"sku":"PAGMV105-5KEPR-4\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036389499194,"sku":"PAGMV105-5KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-4-0-3c-5kv-mv105-armored-power-cable.jpg?v=1771451311"},{"product_id":"2-awg-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"2 AWG 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #10\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e185 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e160 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e12 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e212 + j42\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 1134 + j26\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036389040442,"sku":"PAGMV105-5KEPR-2-250","price":8210.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036389073210,"sku":"PAGMV105-5KEPR-2-500","price":16337.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036389105978,"sku":"PAGMV105-5KEPR-2-1K","price":32507.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036389138746,"sku":"PAGMV105-5KEPR-2-2500","price":80850.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036389171514,"sku":"PAGMV105-5KEPR-2-FT","price":33.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-2-awg-3c-5kv-mv105-armored-power-cable.jpg?v=1771451237"},{"product_id":"2-0-awg-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"2\/0 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #8\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e275 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e235 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e14 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e 106 + j37\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 888 + j2\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036389204282,"sku":"PAGMV105-5KEPR-2\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036389237050,"sku":"PAGMV105-5KEPR-2\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036389269818,"sku":"PAGMV105-5KEPR-2\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036389302586,"sku":"PAGMV105-5KEPR-2\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036389335354,"sku":"PAGMV105-5KEPR-2\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-2-0-3c-5kv-mv105-armored-power-cable.jpg?v=1771451284"},{"product_id":"1-0-awg-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"1\/0 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #8\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e240 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e210 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e14 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e134 + j39\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 954 + j22\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036388876602,"sku":"PAGMV105-5KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036388909370,"sku":"PAGMV105-5KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036388942138,"sku":"PAGMV105-5KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036388974906,"sku":"PAGMV105-5KEPR-1\/0-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036389007674,"sku":"PAGMV105-5KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-1-0-3c-5kv-mv105-armored-power-cable.jpg?v=1771451389"},{"product_id":"250-mcm-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"250 MCM 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #6\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e400 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e335 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e17 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e  57 + j34\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 704 + j18\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036389957946,"sku":"PAGMV105-5KEPR-250-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036389990714,"sku":"PAGMV105-5KEPR-250-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036390023482,"sku":"PAGMV105-5KEPR-250-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036390056250,"sku":"PAGMV105-5KEPR-250-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036390089018,"sku":"PAGMV105-5KEPR-250-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-250-mcm-3c-5kv-mv105-armored-power-cable.jpg?v=1771451160"},{"product_id":"350-mcm-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"350 MCM 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #6\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e490 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e400 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e18 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e  41 + j32\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 622 + j16\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036390121786,"sku":"PAGMV105-5KEPR-350-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036390154554,"sku":"PAGMV105-5KEPR-350-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036390187322,"sku":"PAGMV105-5KEPR-350-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036390220090,"sku":"PAGMV105-5KEPR-350-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036390252858,"sku":"PAGMV105-5KEPR-350-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-350-mcm-3c-5kv-mv105-armored-power-cable.jpg?v=1771451110"},{"product_id":"500-mcm-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"500 MCM 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #5\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e600 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e485 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e20 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e   29 + j31\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e 548 + j15\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036390285626,"sku":"PAGMV105-5KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036390318394,"sku":"PAGMV105-5KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036390351162,"sku":"PAGMV105-5KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036390383930,"sku":"PAGMV105-5KEPR-500-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036390416698,"sku":"PAGMV105-5KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-500-mcm-3c-5kv-mv105-armored-power-cable.jpg?v=1771451060"},{"product_id":"750-mcm-3c-5kv-133-prysmian-airguard-mv-105-cable","title":"750 MCM 3C Prysmian Airguard™ 5kV 133% MV-105 Power Cable","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003ePrysmian’s patented AIRGUARD cable\u003c\/strong\u003e is a direct replacement for continuously corrugated and welded aluminum armored cables (*in Class 1 Div 2 locations) with 5X the impact performance and up to 3X the sidewall bearing pressure limit (at 3000 lbs per rad-ft) This enables longer pulls than with CCW type cables.Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX™ EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, cabled with fillers and grounding conductors, overall binder tape, foamed polymeric AIR BAG™layer for superior mechanical protection, longitudinally applied aluminum tape, extruded oil and hydrocarbon resistant polymeric DRYLAM™ layer, and overall sunlight resistant PVC jacket. Suitable for Class I Division 2 locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eClass B Compact concentric strand soft drawn annealed copper per ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eNatural high dielectric strength EPROTENAX™ EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003cbr\u003e\u003c\/strong\u003eExtruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied non-magnetic copper tape(s) over the insulation shield with a nominal overlap of 25%. A mylar ribbon is longitudinally applied under the copper tape shield for phase identification - 1C w\/ Red, 1C w\/ Blue, and 1C w\/ Black.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUNDING CONDUCTORS:\u003cbr\u003e\u003c\/strong\u003eBare stranded copper conductor per UL, ICEA, and ASTM.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eASSEMBLY:\u003cbr\u003e\u003c\/strong\u003ePhase identified conductors cabled with fillers and grounding conductors, forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMECHANICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eHigh strength and high crush resistant AIR BAG layer extruded over the core assembly.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCHEMICAL PROTECTION:\u003cbr\u003e\u003c\/strong\u003eA layer of DRYLAM™ which consists of a 6mil longitudinally applied aluminum tape and a chemical resistant extruded polymer layer is applied.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack jacket of linear lows density polyethylene (LLDPE), which is sunlight, abrasion and heat resistant. The jacket has 3 red stripes, the NESC lightning bolt and sequential footage markings.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGROUND WIRES:\u003cbr\u003e\u003c\/strong\u003e3 - #4\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eIn Air \/ Tray @ 105°C - \u003cstrong\u003e745 Amps\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eIn Duct @ 105°C - \u003cstrong\u003e585 Amps\u003cbr\u003e\u003cbr\u003eMinimum Bending Radius:\u003cbr\u003e\u003c\/strong\u003e23 in.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance:\u003cbr\u003e\u003c\/strong\u003ePos\/Neg Seq -  \u003cstrong\u003e   20 + j30\u003cbr\u003e\u003c\/strong\u003eZero Seq -  \u003cstrong\u003e  465 + j13\u003c\/strong\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53036390482234,"sku":"PAGMV105-5KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53036390515002,"sku":"PAGMV105-5KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53036390547770,"sku":"PAGMV105-5KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2500 ft. Spool","offer_id":53036390580538,"sku":"PAGMV105-5KEPR-750-2500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53036390613306,"sku":"PAGMV105-5KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/prysmian-airguard-750-mcm-3c-5kv-mv105-armored-power-cable.jpg?v=1771451013"}],"url":"https:\/\/www.wireamerica.com\/collections\/mv-105-5kv-15kv-35kv-medium-voltage-cable.oembed","provider":"Wire America ","version":"1.0","type":"link"}