{"title":"ALUMINUM MV-105 15kV-35kV","description":"\u003cp\u003e\u003cstrong\u003eAluminum MV-105 (15kV–35kV)\u003c\/strong\u003e is a heavy-duty medium-voltage cable used for primary power distribution in industrial plants and utility grids. Its \"105\" rating means it can safely operate at higher temperatures (\u003cstrong\u003e105°C\u003c\/strong\u003e) than standard cables, allowing it to carry more current. It is engineered for durability in conduits, underground ducts, or direct burial, making it the standard for high-voltage reliability. \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eRead our \u003c\/span\u003e\u003ca title=\"Aluminum MV-105: 15kV – 35kV Medium Voltage Power Cable Buyers Guide\" href=\"https:\/\/wireamerica.com\/blogs\/news\/aluminum-mv-105-buying-guide-15kv-35kv-medium-voltage-power\"\u003e\u003cspan\u003e\u003cstrong\u003eAluminum MV-105 15kV-35kV Buyers Guide\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eNeed a quote? \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eCall us at:\u003c\/span\u003e 833-268-8644 \u003cmeta charset=\"utf-8\"\u003e \u003cspan style=\"color: rgb(64, 64, 64);\"\u003eor e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003email: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003esales@wireamerica.com\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"1-0-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"1\/0 Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e170 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e155 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 170 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969767829818,"sku":"MV105AL-15KEPR-1\/0-250","price":2180.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969767862586,"sku":"MV105AL-15KEPR-1\/0-500","price":4337.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969767895354,"sku":"MV105AL-15KEPR-1\/0-1K","price":8629.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969767928122,"sku":"MV105AL-15KEPR-1\/0-FT","price":8.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-1-0-133-UL1072.jpg?v=1770999996"},{"product_id":"2-awg-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"2 AWG Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 115 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e130 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e120 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e130 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969767436602,"sku":"MV105AL-15KEPR-2-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969767469370,"sku":"MV105AL-15KEPR-2-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969767502138,"sku":"MV105AL-15KEPR-2-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969767534906,"sku":"MV105AL-15KEPR-2-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-2-awg-133-UL1072.jpg?v=1771000015"},{"product_id":"4-0-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"4\/0 Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 230 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e260 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e230 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e245 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 235 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 265 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969767698746,"sku":"MV105AL-15KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969767731514,"sku":"MV105AL-15KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969767764282,"sku":"MV105AL-15KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969767797050,"sku":"MV105AL-15KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-4-0-133-UL1072.jpg?v=1770999970"},{"product_id":"2-0-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"2\/0 Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 175 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e200 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e175 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e190 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 175 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969767567674,"sku":"MV105AL-15KEPR-2\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969767600442,"sku":"MV105AL-15KEPR-2\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969767633210,"sku":"MV105AL-15KEPR-2\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969767665978,"sku":"MV105AL-15KEPR-2\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-2-0-133-UL1072.jpg?v=1770999940"},{"product_id":"250-mcm-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"250 MCM Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 255 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e290 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e250 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e270 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 260 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 290 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969769271610,"sku":"MV105AL-15KEPR-250-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969769304378,"sku":"MV105AL-15KEPR-250-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969769337146,"sku":"MV105AL-15KEPR-250-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969769369914,"sku":"MV105AL-15KEPR-250-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-250-MCM-133-UL1072.jpg?v=1770999921"},{"product_id":"350-mcm-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"350 MCM Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 310 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e350 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e305 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e330 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 325 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 360 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969769140538,"sku":"MV105AL-15KEPR-350-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969769173306,"sku":"MV105AL-15KEPR-350-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969769206074,"sku":"MV105AL-15KEPR-350-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969769238842,"sku":"MV105AL-15KEPR-350-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-350-MCM-133-UL1072.jpg?v=1770999864"},{"product_id":"500-mcm-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"500 MCM Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 385 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e430 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e370 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e400 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 400 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 450 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969769566522,"sku":"MV105AL-15KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969769599290,"sku":"MV105AL-15KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969769632058,"sku":"MV105AL-15KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969769664826,"sku":"MV105AL-15KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-500-MCM-133-UL1072.jpg?v=1770999885"},{"product_id":"750-mcm-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"750 MCM Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 485 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e540 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e455 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e490 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 515 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 585 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969769697594,"sku":"MV105AL-15KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969769730362,"sku":"MV105AL-15KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969769763130,"sku":"MV105AL-15KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969769795898,"sku":"MV105AL-15KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-750-MCM-133-UL1072.jpg?v=1770999902"},{"product_id":"1000-mcm-aluminum-mv-105-15kv-cable-epr-pvc-copper-tape-shield","title":"1000 MCM Aluminum MV-105 Cable 15kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 15KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 15kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength EPR insulation with or without lead, contrasting in color to the black semi-conducting shield layers, extruded over the conductor shield.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded, strippable semi-conducting layer over the insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 565 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e640 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e525 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e565 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 620 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 705 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 311.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 311.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 311.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 311.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 311.60(C)(69).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969770746170,"sku":"MV105AL-15KEPR-1000-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969770778938,"sku":"MV105AL-15KEPR-1000-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969770811706,"sku":"MV105AL-15KEPR-1000-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969770844474,"sku":"MV105AL-15KEPR-1000-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-1000-MCM-133-UL1072.jpg?v=1770999831"},{"product_id":"1-0-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"1\/0 Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e170 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e155 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 170 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969770877242,"sku":"MV105AL-35KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969770910010,"sku":"MV105AL-35KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969770942778,"sku":"MV105AL-35KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969770975546,"sku":"MV105AL-35KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-1-0-Copper_Tape-epr.jpg?v=1770999707"},{"product_id":"2-0-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"2\/0 Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 175 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e200 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e175 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e190 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 175 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 195 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969771368762,"sku":"MV105AL-35KEPR-2\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969771401530,"sku":"MV105AL-35KEPR-2\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969771434298,"sku":"MV105AL-35KEPR-2\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969771467066,"sku":"MV105AL-35KEPR-2\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-2-0-copper-tape-epr.jpg?v=1770999787"},{"product_id":"4-0-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"4\/0 Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 230 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e260 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e230 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e245 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 235 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 260 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969771008314,"sku":"MV105AL-35KEPR-4\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969771041082,"sku":"MV105AL-35KEPR-4\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969771073850,"sku":"MV105AL-35KEPR-4\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969771106618,"sku":"MV105AL-35KEPR-4\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-4-0.jpg?v=1770999631"},{"product_id":"250-mcm-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"250 MCM Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 255 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e290 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e250 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e270 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 260 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 285 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969772581178,"sku":"MV105AL-35KEPR-250-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969772613946,"sku":"MV105AL-35KEPR-250-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969772646714,"sku":"MV105AL-35KEPR-250-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969772679482,"sku":"MV105AL-35KEPR-250-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-250-MCM.jpg?v=1770999548"},{"product_id":"350-mcm-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"350 MCM Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 310 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e350  Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e305 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e330 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 325 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 355 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969772843322,"sku":"MV105AL-35KEPR-350-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969772876090,"sku":"MV105AL-35KEPR-350-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969772908858,"sku":"MV105AL-35KEPR-350-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969772941626,"sku":"MV105AL-35KEPR-350-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-350-MCM.jpg?v=1770999527"},{"product_id":"500-mcm-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"500 MCM Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 385 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e430 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e370 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e400 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 400 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 445 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969772974394,"sku":"MV105AL-35KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969773007162,"sku":"MV105AL-35KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969773039930,"sku":"MV105AL-35KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969773072698,"sku":"MV105AL-35KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-500-MCM.jpg?v=1770999442"},{"product_id":"750-mcm-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"750 MCM Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 485 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e540 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e455\u003c\/strong\u003e \u003cstrong\u003eAmps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e490 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 515 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 575 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969772712250,"sku":"MV105AL-35KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969772745018,"sku":"MV105AL-35KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969772777786,"sku":"MV105AL-35KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969772810554,"sku":"MV105AL-35KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-750-MCM.jpg?v=1770999491"},{"product_id":"1000-mcm-aluminum-mv-105-35kv-cable-epr-pvc-copper-tape-shield","title":"1000 MCM Aluminum MV-105 Cable 35kV | 100% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 565 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e640 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e525\u003c\/strong\u003e \u003cstrong\u003eAmps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e565 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 620 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 690 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":52969774055738,"sku":"MV105AL-35KEPR-1000-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":52969774088506,"sku":"MV105AL-35KEPR-1000-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":52969774121274,"sku":"MV105AL-35KEPR-1000-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":52969774154042,"sku":"MV105AL-35KEPR-1000-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-1000-MCM.jpg?v=1770999424"},{"product_id":"750-mcm-aluminum-mv-105-medium-voltage-cable-35kv","title":"750 MCM Aluminum MV-105 Cable 35kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 485 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e540 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e455 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e490 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 515 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 575 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53003487445306,"sku":"MV105ALV-35KEPR-750-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53003487478074,"sku":"MV105ALV-35KEPR-750-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53003487510842,"sku":"MV105ALV-35KEPR-750-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53003487543610,"sku":"MV105ALV-35KEPR-750-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-750.jpg?v=1770822484"},{"product_id":"1-0-aluminum-mv-105-medium-voltage-cable-35kv","title":"1\/0 Aluminum MV-105 Cable 35kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - \u003cstrong\u003e170 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e155 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e165 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 150 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 170 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53003487707450,"sku":"MV105ALV-35KEPR-1\/0-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53003487740218,"sku":"MV105ALV-35KEPR-1\/0-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53003487772986,"sku":"MV105ALV-35KEPR-1\/0-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53003487805754,"sku":"MV105ALV-35KEPR-1\/0-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-1-0.jpg?v=1770822578"},{"product_id":"500-mcm-aluminum-mv-105-medium-voltage-cable-35kv","title":"500 MCM Aluminum MV-105 Cable 35kV | 133% Insulation Copper Tape Shield","description":"\u003cstrong\u003eAPPLICATION:\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShielded Aluminum MV-105 35KV\u003c\/strong\u003e cable is primarily used for power circuits in commercial, industrial, refinery and petro-chemical plants; utility power generation and substations. The cable can be installed in wet or dry applications and is for use in aerial, conduit, open tray, and underground duct installations. It can be used in direct burial if installed with a ground conductor in close proximity. The cable is approved for temperature up to 105°C and voltages up to 35kV.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTORS:\u003c\/strong\u003e\u003cbr\u003eStranded 1350 series aluminum, compact Class B stranding per ASTM\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCONDUCTOR SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting stress-control layer over conductor.\u003cbr\u003e\u003cstrong\u003e\u003cbr\u003eINSULATION:\u003c\/strong\u003e\u003cbr\u003eHigh dielectric strength lead-free EPR insulation, contrasting in color to the black semi-conducting shield layers.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eINSULATION SHIELD:\u003c\/strong\u003e\u003cbr\u003eExtruded thermoset semi-conducting polymeric layer free stripping from insulation.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMETALLIC SHIELD:\u003cbr\u003e\u003c\/strong\u003eHelically applied 5 mil annealed copper tape over the insulation shield with an overlap of 25%.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eJACKET:\u003cbr\u003e\u003c\/strong\u003eBlack low-friction, lead-free, flame-retardant, moisture and sunlight resistant polyvinyl chloride (PVC) jacket tightly applied over the copper tape.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAMP RATINGS:\u003c\/strong\u003e\u003cbr\u003eConduit \/ Air @ 90°C -\u003cstrong\u003e 385 Amps\u003cbr\u003e\u003c\/strong\u003eConduit \/ Air @ 105°C - 430\u003cstrong\u003e Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 90°C - \u003cstrong\u003e370 Amps\u003cbr\u003e\u003c\/strong\u003eUnderground \/ Duct @ 105°C - \u003cstrong\u003e400 Amps\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003eTray @ 90°C -\u003cstrong\u003e 400 Amps\u003cbr\u003e\u003c\/strong\u003eTray @ 105°C -\u003cstrong\u003e 445 Amps\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003cem\u003eAll values are nominal and subject to correction * Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). ** Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. *** Ampacities are based on single conductor Type MV-105 sizes #1\/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70).\u003c\/em\u003e","brand":"Wire America","offers":[{"title":"250 ft. Spool","offer_id":53003487576378,"sku":"MV105ALV-35KEPR-500-250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"500 ft. Spool","offer_id":53003487609146,"sku":"MV105ALV-35KEPR-500-500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft. Spool","offer_id":53003487641914,"sku":"MV105ALV-35KEPR-500-1K","price":0.0,"currency_code":"USD","in_stock":true},{"title":"By the Foot","offer_id":53003487674682,"sku":"MV105ALV-35KEPR-500-FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0969\/0234\/9114\/files\/Aluminum-MV-105-35kV-500.jpg?v=1770822371"}],"url":"https:\/\/www.wireamerica.com\/collections\/aluminum-mv-105-15kv-35kv.oembed","provider":"Wire America ","version":"1.0","type":"link"}